Streamline fire assessments, manage compliance workflows, keep up with Australian standards, and deliver reports with confidence - nine NCC tools in one intelligent platform.
Built for compliance with Australian Standards
Powerful tools designed for fire engineering professionals across Australia.
All outputs meet National Construction Code requirements. Updated for NCC 2022/2025.
Generate reports in minutes instead of hours. AI-assisted assessments speed up your workflow.
Export polished PDF reports ready for council submission or client delivery.
Your data stays yours. Bank-level encryption, Australian servers, GDPR compliant.
Automatic updates when standards change. Never worry about outdated templates.
Sydney-based team. Real humans who understand fire engineering.
Built for every workflow
Create and manage fire engineering assessments with ease.
Generate compliant PDF reports with automated calculations.
Organise projects, documents and client information.
Access Australian standards and guidance in one place.
Use built-in templates to save time and stay consistent.
Track performance, identify trends and improve outcomes.
Everything you need for fire & building compliance in a single, integrated platform.
Determine all required fire systems. Ask questions in plain English. Full NCC compliance assessment with PDF reports.
Generate formal fire safety schedules for Construction Certificates. All 8 states supported.
Track essential safety measures, schedule inspections, manage defects, generate annual statements.
Bushfire Attack Level assessment. Vegetation class, distance, slope, state FDI. Construction requirements per BAL level.
Occupant loads, exit widths, travel distances, fire stair capacity, accessibility compliance.
Construction-phase compliance tracking for fire-rated walls, doors, penetrations, dampers.
Look up tested fire-rated construction systems by FRL requirement. Manufacturer data and test reports.
Emergency procedures, warden organisation charts, evacuation diagram checklists, emergency contacts.
NCC 2025 energy efficiency assessment. R-values, glazing, HVAC, mandatory solar PV, EV charging, condensation.
Fire Suite is Australian fire and building compliance software for engineers, certifiers, building surveyors, facility managers and passive fire teams. Create NCC fire system assessments, fire safety schedules, AS 1851 inspection plans, AFSS and ESM reports, BAL calculations, egress checks, passive fire registers, FRL lookups, evacuation plans and Section J energy assessments in one platform.
The Fire System Requirements tool works through the inputs an NCC fire assessment turns on - building class, effective height, rise in storeys, floor area and hazard level - and helps you determine which systems apply: sprinklers and hydrants, detection and alarm, smoke hazard management and occupant-load driven measures. It references the NCC alongside standards such as AS 2118 (sprinklers), AS 2419 (hydrants) and AS 1670 (detection and alarm), then produces a clear report you can attach to your assessment.
AS 1851 covers the routine service - inspection, testing and preventive maintenance - of fire protection systems and equipment. The ESM Manager and Fire Safety Schedule tools turn that into a working schedule: each measure with its Australian Standard, NCC clause, AS 1851 baseline frequency and critical test, plus tracking for due and overdue tasks, defects and rectification dates, ready for annual statement preparation.
Fire compliance language changes across the country. New South Wales requires an Annual Fire Safety Statement (AFSS) that confirms each essential fire safety measure for a building; Victoria uses Essential Safety Measures (ESM) and an annual ESM report; Queensland and the other states and territories use their own equivalent schedules and statements. Fire Suite maps your measures to the terminology and cadence your jurisdiction expects - see the NSW, Victoria and Queensland guides, or browse all states and territories.
Passive fire is where compliance is most often lost on site. The Passive Fire Tracker keeps a register of fire-rated walls, floors and doors, penetration seals, dampers, collars, shaft walls and linear joint seals - the service penetrations and control joints covered by AS 4072.1 - so nothing is missed between design and handover. Pair it with the FRL Detailing tool to look up fire-resistance levels and tested systems referenced to AS 1530.4.
For building in bushfire-prone areas, the BAL Calculator assesses the Bushfire Attack Level to AS 3959, working from vegetation classification, distance to the hazard, slope and the relevant Fire Danger Index. It gives you a BAL rating from BAL-LOW to BAL-FZ to inform the construction requirements for the site.
The suite closes out the rest of the pipeline too: the Exit and Egress Design tool checks exit provision and travel distances under the NCC, the Evacuation Plan Generator builds emergency plans and the emergency control organisation to AS 3745, and the Section J tool handles NCC 2025 energy assessment.
Fire Suite is built in Sydney for Australian practice and maintained for the current NCC (2022 and 2025 editions) as each is adopted across the states and territories. The tools reference the standards their workflows depend on - including AS 1670, AS 2118, AS 2419, AS 1851, AS 3745, AS 3959, AS 1530.4, AS 4072.1 and NCC 2025 Section J - and are updated when those standards or the NCC change.
Each tool is a professional calculation and documentation aid, not an official certification document. Outputs should always be verified against the current NCC and the relevant Australian Standards by a suitably qualified practitioner - a fire safety engineer, building surveyor, certifier or accredited ESM practitioner - before they are relied on for certification or lodgement.
Billed annually - your first month is free. 14-day free trial, cancel anytime, no lock-in.
1 user
$539 billed annually 1 month free
Up to 5 users
$1,639 billed annually 1 month free
Up to 20 users
$4,389 billed annually 1 month free
Not satisfied? Get a full refund within 30 days, no questions asked.
Purpose-built for Australian fire engineering practice - accurate to the standards, fast to use, and backed by people who understand compliance.
Full access to all 9 tools: Fire System Requirements + AI, Fire Safety Schedule, ESM Manager, BAL Calculator, Exit & Egress Design, Passive Fire Tracker, FRL Detailing, Evacuation Plan Generator, and the NCC 2025 Section J Energy tool. Plus unlimited assessments, PDF exports, and priority support.
Yes. All tools are designed for NCC 2022/2025 compliance and reference relevant Australian Standards including AS1670, AS2118, AS2419, AS1851, AS3745, AS3959, AS1530.4, AS4072.1, and NCC 2025 Section J. We update the software when standards change.
Absolutely. No lock-in contracts, no cancellation fees. Cancel from your dashboard with one click. Your data remains accessible for 30 days after cancellation.
Yes. We use bank-level encryption (AES-256), Australian-hosted servers, and are GDPR compliant. Your project data is never shared or used for training AI models.
Yes. The Small Business plan includes up to 5 users and the Large Company plan up to 20, with shared projects across your team. Need more seats? Contact us about enterprise pricing.
Start with 14 days free access to everything. No credit card required. If you love it, subscribe. If not, no charge - your trial simply ends.
Occasional product news and tips. No spam; unsubscribe anytime.